ABSTRACT

With the continuous expansion and increasing complexity of the power system, the protection requirements for the power system are also increasing. Although traditional relay protection systems can play a certain protective role, they have some limitations, such as the inability to comprehensively monitor the power system and the lack of accurate judgment. Developing and applying intelligent relay protection systems has become an important way to improve the safety and reliability of power systems. This article explored the relay protection strategies and practices for power systems under extreme weather conditions. Traditional relay protection systems have limitations in addressing the increasingly complex protection needs of power systems. Therefore, the development and application of intelligent relay protection systems have become a key way to improve the safety and reliability of power systems. This article verified the effectiveness of the knowledge base based relay protection fault handling process in improving the safety, stability, and fault handling efficiency of power systems through experimental results and discussions. The experimental results showed that under different fault conditions, the processing accuracy was generally high, and in the vast majority of cases, the accuracy exceeded 90%. For example, the accuracy of handling line short circuits and voltage anomalies was 95% and 96%, respectively.

KEYWORDS

Power System; Relay Protection; Fault Detection; Knowledge Base

CITE THIS PAPER

Shuang Yan, Qingxin Meng, Strategy and Practice of Power System Relay Protection under Extreme Weather Conditions. Journal of Electrotechnology, Electrical Engineering and Management (2024) Vol. 7: 20-27. DOI: http://dx.doi.org/10.23977/jeeem.2024.070204.

REFERENCES

[1] Faazila Fathima S, Premalatha L. Protection strategies for ac and dc microgrid–A review of protection methods adopted in recent decade[J]. IETE Journal of Research, 2023, 69(9): 6573-6589.
[2] Alhadrawi Z, Abdullah M N, Mokhlis H. Review of microgrid protection strategies: current status and future prospects [J]. TELKOMNIKA (Telecommunication Computing Electronics and Control), 2022, 20(1): 173-184.
[3] Hojjaty M, Fani B, Sadeghkhani I. Intelligent protection coordination restoration strategy for active distribution networks [J]. IET Generation, Transmission & Distribution, 2022, 16(3): 397-413.
[4] Wang Q. Feeder segment switch-based relay protection for a multilayer differential defense-oriented distribution network [J]. Soft Computing, 2022, 26(10): 4895-4904.
[5] Yousaf M, Jalilian A, Muttaqi K M, et al. An adaptive overcurrent protection scheme for dual-setting directional recloser and fuse coordination in unbalanced distribution networks with distributed generation[J]. IEEE Transactions on Industry Applications, 2022, 58(2): 1831-1842.
[6] Wei X, Yang J. Progress in research on relay protection of the power system with large-scale wind power access[J]. Journal of Electrotechnology, Electrical Engineering and Management, 2023, 6(3): 26-29.
[7] Li F, Zhuyuan L. A summary of relay protection-based simulation for Dynamic Performance and Reliability Assessment [J]. International Journal for Applied Information Management, 2023, 3(1): 11-23.
[8] Yuming H, Jiaohong L, Zhenguo M, et al. On combined PSO-SVM models in fault prediction of relay protection equipment [J]. Circuits, Systems, and Signal Processing, 2023, 42(2): 875-891.
[9] Andreev M, Bay Y, Malyuta B. Novel method for setting up the relay protection of power systems containing renewable energy sources and hydrogen energy storage systems[J]. International Journal of Hydrogen Energy, 2023, 48(76): 29425-29445.
[10] El-Sayed L M A, Ibrahim D K, Gilany M I. Enhancing distance relay performance using wide-area protection for detecting symmetrical/unsymmetrical faults during power swings[J]. Alexandria Engineering Journal, 2022, 61(9): 6869-6886.
[11] Reda A, Abdelgawad A F, Ibrahim M. Effect of non standard characteristics of overcurrent relay on protection coordination and maximizing overcurrent protection level in distribution network[J]. Alexandria Engineering Journal, 2022, 61(9): 6851-6867.
[12] Yang Z, Liao W, Zhang Q, et al. Fault coordination control for converter-interfaced sources compatible with distance protection during asymmetrical faults[J]. IEEE Transactions on Industrial Electronics, 2022, 70(7): 6941-6952.
[13] Zhiren L, Weilin T, Mingjun X, et al. Differential protection strategy for distribution network based on 5G communication[J]. IET Generation, Transmission & Distribution, 2023, 17(9): 2028-2037.
[14] Ataee‐Kachoee A H, Hashemi‐Dezaki H, Ketabi A. Optimal adaptive protection of smart grids using high‐set relays and smart selection of relay tripping characteristics considering different network configurations and operation modes [J]. IET Generation, Transmission & Distribution, 2022, 16(24): 5084-5116.
[15] Rostami A, Rezaei N. A reliable and straightforward index to avoid nuisance trip of the conventional Z‐based loss‐of‐field relay in synchronous generators[J]. IET Generation, Transmission & Distribution, 2022, 16(6): 1201-1211.
[16] Bakkar M, Bogarra S, Córcoles F, et al. Multi-layer smart fault protection for secure smart grids[J]. IEEE Transactions on Smart Grid, 2022, 14(4): 3125-3135.
[17] Tiwari R, Singh R K, Choudhary N K. Coordination of dual setting overcurrent relays in microgrid with optimally determined relay characteristics for dual operating modes[J]. Protection and Control of Modern Power Systems, 2022, 7(1): 1-18.
[18] Wang Z, Mu L, Fang C. Renewable microgrid protection strategy coordinating with current-based fault control[J]. Journal of Modern Power Systems and Clean Energy, 2022, 10(6): 1679-1689.
[19] Yousefi kia M, Saniei M, Seifossadat S G. A novel cyber‐attack modelling and detection in overcurrent protection relays based on wavelet signature analysis[J]. IET Generation, Transmission & Distribution, 2023, 17(7): 1585-1600.

Downloads: 2732